• 1-1/8′′ EVR 20 Cold Refrigeration Solenoid Valve For Air Condition 032F1244 12V 24V 110V 220V
  • 1-1/8′′ EVR 20 Cold Refrigeration Solenoid Valve For Air Condition 032F1244 12V 24V 110V 220V
  • 1-1/8′′ EVR 20 Cold Refrigeration Solenoid Valve For Air Condition 032F1244 12V 24V 110V 220V
  • 1-1/8′′ EVR 20 Cold Refrigeration Solenoid Valve For Air Condition 032F1244 12V 24V 110V 220V
  • 1-1/8′′ EVR 20 Cold Refrigeration Solenoid Valve For Air Condition 032F1244 12V 24V 110V 220V
  • 1-1/8′′ EVR 20 Cold Refrigeration Solenoid Valve For Air Condition 032F1244 12V 24V 110V 220V

1-1/8′′ EVR 20 Cold Refrigeration Solenoid Valve For Air Condition 032F1244 12V 24V 110V 220V

Actuator: Solenoid
Type: Pilot Operated
Material: Brass
Pressure: 0.05 to 21 bar
Power Supply: AC, DC
Usage: Flow Control
Customization:
Diamond Member Since 2022

Suppliers with verified business licenses

Rating: 5.0/5
Manufacturer/Factory
  • Overview
  • Product Description
  • Technical Data
  • Production Process
  • Payment & Delivery
  • FAQ
Overview

Basic Info.

Model NO.
EVR20-118S
Standard
GB
Application
Industrial Usage
Port Size
1-1/8′′
Conncetion
ODF (Solder)
Function
2 Way Normally Closed
Product Name
Refrigeration Solenoid Valve
Medium Temperature Range
-40~105ºC
KV Factor( m³/h)
5
Coil Type
BE, BF, BG
Voltage
12VDC, 24VDC, 24VAC, 110VAC, 220VAC
Transport Package
Box, Carton, Pallet
Trademark
BRANDO
Origin
Ningbo, China
HS Code
8481804090
Production Capacity
10000 PCS Per Month

Product Description

 
Product Description

The EVR20-118S is a diaphragm pilot operated refrigeration solenoid valve with 1-1/8" port size, 5m³/ h KV value, 2 way normally closed type, and the general working coil temperature range is -40~105ºC. It is designed for medium temperatures up to 105ºC. This type of valve is widely used in various refrigeration systems, such as air conditioning equipment, air conditioning units, compressors and so on.

Options for you:
1. Connection Type: Solder (ODF), Flare (SAE)
2. Port Size: 1/4'', 3/8'', 1/2'', 5/8'', 3/4'' , 7/8'', 1 1/8'', 1 3/8'', 1 5/8'', 2 1/8''
3. Voltage: 12VDC, 24VDC, 24VAC, 110VAC, 220VAC
4. 
Coil Type: BE (Clip on type, Terminal box), BF (Clip on type, Flying leads), BG (Clip on type, Terminal box)

Technical Data
 
Type Current Type Port Size Connection
Size (mm)
Max. Working
Pressure (bar)
KV Valve
(m³/h)
Code no.
EVR 2 AC 1/4 " 6 45.2 0.15 032F1201
EVR 3 AC / DC 1/4 " 6 45.2 0.26 032F1206
AC / DC 3/8 " 10 45.2 0.26 032F1204
EVR 6 AC / DC 3/8 " 10 45.2 0.80 032F1212
AC / DC 1/2 " 12 45.2 0.80 032F1209
EVR 10 AC / DC 1/2 " 12 35 1.9 032F1217
AC / DC 5/8 " 16 35 1.9 032F1214
EVR 15 AC / DC 5/8 " 16 32 2.6 032F1228
AC / DC 7/8 " 22 32 2.6 032F1225
EVR 20 AC 7/8 " 22 32 5.0 032F1240
DC 7/8 " 22 32 5.0 032F1264
AC 1 1/8 " 28 32 5.0 032F1244
EVR 22 AC 1 3/8 " 35 32 6.0 032F3267
EVR 25 AC / DC 1 1/8 " 28 32 10.0 032F2201
AC / DC 1 3/8 " 35 32 10.0 032F2208
EVR 32 AC / DC 1 5/8 " 42 32 16.0 042H1104
EVR 40 AC / DC 1 5/8 " 42 32 25.0 042H1110
AC / DC 2 1/8 " 42 32 25.0 042H1112

 

1-1/8′′ EVR 20 Cold Refrigeration Solenoid Valve For Air Condition 032F1244 12V 24V 110V 220V
1-1/8′′ EVR 20 Cold Refrigeration Solenoid Valve For Air Condition 032F1244 12V 24V 110V 220V
1-1/8′′ EVR 20 Cold Refrigeration Solenoid Valve For Air Condition 032F1244 12V 24V 110V 220V
1-1/8′′ EVR 20 Cold Refrigeration Solenoid Valve For Air Condition 032F1244 12V 24V 110V 220V
BE                                                BG                                                     BF
1-1/8′′ EVR 20 Cold Refrigeration Solenoid Valve For Air Condition 032F1244 12V 24V 110V 220V
1-1/8′′ EVR 20 Cold Refrigeration Solenoid Valve For Air Condition 032F1244 12V 24V 110V 220V
Production Process
1-1/8′′ EVR 20 Cold Refrigeration Solenoid Valve For Air Condition 032F1244 12V 24V 110V 220V
1-1/8′′ EVR 20 Cold Refrigeration Solenoid Valve For Air Condition 032F1244 12V 24V 110V 220V
Payment & Delivery
1-1/8′′ EVR 20 Cold Refrigeration Solenoid Valve For Air Condition 032F1244 12V 24V 110V 220V
1-1/8′′ EVR 20 Cold Refrigeration Solenoid Valve For Air Condition 032F1244 12V 24V 110V 220V
FAQ

Question 1: What is a solenoid valve used for?
Answer 1: A solenoid valve is used to open, close, mix, or divert media in an application. They are used in a wide variety of applications.

Question 2: How can you tell if your solenoid is bad?
Answer 2: If the solenoid valve fails to open or close, is partially open, makes a humming noise or has a burned-out coil, you need to troubleshoot the valve solenoids.

Question 3: How do I choose a solenoid valve?
Answer 3: When choosing a solenoid valve, it is important to know your media. Depending upon the media and flow requirement, choose the material, orifice size, temperature, pressure, voltage, response time and certification required for your application.

 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now

You Might Also Like

Product Groups

Diamond Member Since 2022

Suppliers with verified business licenses

Rating: 5.0/5
Manufacturer/Factory
Plant Area
101~500 square meters
Export Year
2008-08-08