Customization: | Available |
---|---|
Customized: | Standard |
Working Medium: | Air |
Still deciding? Get samples of US$ 20/Piece
Order Sample
|
Shipping Cost: | Contact the supplier about freight and estimated delivery time. |
---|
Payment Methods: |
|
---|---|
Support payments in USD |
Secure payments: | Every payment you make on Made-in-China.com is protected by the platform. |
---|
Refund policy: | Claim a refund if your order doesn't ship, is missing, or arrives with product issues. |
---|
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
Pneumatic filter regulator lubricator (FRL) is used to deliver clean air, at a fixed pressure, and lubricated (if needed) to ensure proper pneumatic component operation and increase their operation lifetime. Filters, regulators, and lubricators can be bought individually or as a package.
1. Filter: remove water, dirt and other harmful debris from an air system. This is often the first step in improving the air quality.
2. Regulator: adjust and control the air pressure of a system to ensure that down-line components do not exceed their maximum operating pressures. This is the second step in the FRL system.
3. Lubricator: reduce the internal friction in tools or equipment by releasing a controlled mist of oil into the compressed air. This is often done last and/or right before the component needing lubrication.
Model | AC1000 | AC2000 | AC2500 | AC3000 | AC4000 | AC4000-06 | AC5000 | AC5500 | AC6000 | |
Combination equipment |
Filter | AF1000 | AF2000 | AF3000 | AF3000 | AF4000 | AF4000-06 | AF5000 | AF6000 | AF6000 |
Regulator | AR1000 | AR2000 | AR2500 | AR3000 | AR4000 | AR4000-06 | AR5000 | AR5000 | AR6000 | |
Lubricator | AL1000 | AL2000 | AL3000 | AL3000 | AL4000 | AL4000-06 | AL5000 | AL6000 | AL6000 | |
Port size | M5 |
1/8'' 1/4'' |
1/4'' 3/8'' |
1/4'' 3/8'' |
1/4'' 3/8'' 1/2'' |
3/4'' | 3/4'' 1'' |
1'' | 1'' | |
Gauge port size | 1/16'' | 1/8'' | 1/8'' | 1/8'' | 1/4'' | 1/4'' | 1/4'' | 1/4'' | 1/4'' | |
Fluid | Air | |||||||||
Proof pressure | 1.5 MPa | |||||||||
Max. operating pressure | 1.0 MPa | |||||||||
Set pressure range | 0.05 to 0.7 MPa | 0.05 to 0.85 MPa | ||||||||
Flow (l/min) (Port size) | 90 (M5 x0.8) | 500 (1/4'') | 1500 (3/8'') | 2000 (3/8'') | 4000 (1/2'') | 4500 (3/4'') | 5000 (3/4'') | 6000 (1'') | 6000 (1'') | |
Ambient and fluid temperature |
-5 to +60ºC (non-freezing) | |||||||||
Filtration | 5 μm | |||||||||
Recommended lubricant | Turbin oil class 1 (ISO VG32) | |||||||||
Bowl material | Polycarbonate | |||||||||
Construction / Reuglator | Relieving style |
Model No
|
Port Size
|
A
|
B
|
C
|
D
|
E
|
F
|
G
|
H
|
AC1000
|
M5
|
91
|
33
|
25.5
|
84.5
|
26
|
25
|
25
|
20
|
AC2000
|
G3/8'', G1/4''
|
140
|
20
|
38
|
125
|
56.8
|
30
|
40
|
24
|
AC2500
|
G1/4'', G3/8''
|
181
|
64
|
38
|
156.5
|
60.8
|
41
|
53
|
35
|
AC3000
|
G1/4'', G3/8''
|
181
|
64
|
38
|
156.5
|
60.8
|
41
|
53
|
35
|
AC4000
|
G3/8'', G1/2''
|
238
|
84
|
41
|
191.5
|
65.5
|
50
|
70
|
40
|
AC4000-06
|
G3/4''
|
253
|
89
|
41
|
193
|
69.5
|
50
|
70
|
40
|
AC5000
|
G3/4'', G1''
|
300
|
105
|
48
|
271.5
|
75.5
|
69.8
|
90
|
50
|